For Hydrogen Leak Detection
The FH2-HY06-GS2 is a newly developed hydrogen detector, specifically designed for preventing hydrogen leaks in fuel-cell vehicles (FCV). For this application, a reliable hydrogen sensors is required and FIS has developed a new catalytic combustion type hydrogen sensor with a minimum mass and wide surface area using a unique technology. The development of this sensor realizes a rapid response speed and strong poisoning resistance against silicone compounds. These features achieve the expected demands for long life in actual applications in automobiles, without any need for replacing detectors over a long period. In combination with sophisticated electronics and software design, FIS offers the following features in hydrogen leak detection.
APPLICATIONS
Industrial gas leak detector
Target gas: Hydrogen
FEATURE
Rapid response speed
High Selectivity
Wide operating/storage temperature range
Compact and light weight
Long life
Target gas | H2 |
Description | Sensor module for detecting hydrogen leakage from fuell cell vehicle (FCV). |
Sensing principal of mounted gas sensor | Catalytic type |
Measurement range | 0 ~ 4 vol.% |
Power supply | 24V (16~32V) DC |
Power consumption | ≤500mW |
Signal output | CAN |
Standard CAN ID | 0x0CFF1C90, 0x0CFF1C91 |
IP code | IP6K7 |
Size | 82.6 (W) x 80.8 (D) × 22.5 (H) mm |
Weight | 60g |